Schneider Electric | XY2CE2A450 | Safety Pull Switch

Call Us +65 8693 8729
phone 0
phone 0
Product

Industrial Automation

XY2CE2A450 - Pull Switch - Key Release - LH Side

  • $672.14

Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CE, LH side -1NC+1 NO, key release pushbutton

Out Of Stock

This product is out of stock, submit your email and we will update once it restock.

range of product Telemecanique Emergency stop rope pull switches XY2C
product or component type      Latching emergency stop rope pull switch
device short name XY2CE
housing colour Red RAL 3000
overvoltage category Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030
local signalling Without pilot light
number of cables 1
trigger cable maximum length 70 m
body material Zamak
cover material Stainless steel
reset By key-release push-button
key number 421
contacts type and composition 1 NC + 1 NO
contact operation Slow-break
trigger cable anchor point LH side
connections - terminals Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
tightening torque 0.8…1.2 N.m
cable entry number 3 plain hole for Pg 13.5 or ISO M20 cable gland
safety level Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
safety reliability data B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
marking CE
mechanical durability 60000 cycles
distance between cable supports 5 m
[Ie] rated operational current 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current      10 A
[Ui] rated insulation voltage 500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1
positive opening With conforming to EN/IEC 60947-5-1
maximum resistance across terminals 25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60269
terminals description ISO n°1 (21-22)NC
(13-14)NO
net weight 1.465 kg
compatibility code XY2CE