Emergency stop switching off, plastic, red mushroom Ø40, Ø22, trigger latching turn to release, 1NC

Out Of Stock

This product is out of stock, submit your email and we will update once it restock.

range of product Harmony XB5
product or component type Emergency switching off push-button
Emergency stop push-button
device short name XB5
bezel material Dark grey plastic
fixing collar material Plastic
head type Standard
mounting diameter 22 mm
sale per indivisible quantity 1
shape of signalling unit head      Round
type of operator Trigger action and mechanical latching
reset Turn to release
Push-pull
operator profile Red mushroom Ø 40 mm, unmarked
contact operation Slow-break
connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1
device presentation Complete product
height 43 mm
width 40 mm
depth 82 mm
terminals description ISO n°1 (11-12)NC
resistance to high-pressure washer 7000000 Pa at 55 °C, distance: 0.1 m
contacts usage Standard contacts
positive opening With conforming to EN/IEC 60947-5-1 appendix K
operating travel 1.5 mm (NC changing electrical state)
4.3 mm (total travel)
mechanical durability 300000 cycles
tightening torque 0.8…1.2 N.m conforming to EN 60947-1
shape of the screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with Pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
contacts material Silver alloy (Ag/Ni)
short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current      10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage 6 kV EN 60947-1
[Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
electrical reliability Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4