  • $31.22

Harmony XB5, Illuminated selector switch, plastic, green, Ø22, 2 positions, stay put, 24 V AC/DC, 1 NO + 1 NC

Out Of Stock

This product is out of stock, submit your email and we will update once it restock.

range of product Harmony XB5
product or component type      Illuminated selector switch
device short name XB5
bezel material Dark grey plastic
head type Standard
mounting diameter 22 mm
sale per indivisible quantity 1
shape of signalling unit head      Round
type of operator Stay put
operator profile Green standard handle
operator position information 2 positions 90°
contacts type and composition      1 NO + 1 NC
contact operation Slow-break
connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1
bulb base Integral LED
[Us] rated supply voltage 24 V AC/DC at 50/60 Hz
operating torque 0.14 N.m NO changing electrical state
mechanical durability 1000000 cycles
tightening torque 0.8…1.2 N.m conforming to EN 60947-1
shape of the screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with Pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
contacts material Silver alloy (Ag/Ni)
short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current      10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage 6 kV EN 60947-1
[Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
electrical reliability Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
signalling type Steady
light source Protected LED
supply voltage limits 19.2…30 V DC
21.6…26.4 V AC
current consumption 18 mA
service life 100000 h at rated voltage and 25 °C
surge withstand 1 kV conforming to IEC 61000-4-5
device presentation Complete product