Schneider Electric | XB5AD21 | Selector Switch

Call Us +65 8693 8729
phone 0
phone 0
Product

Industrial Automation

XB5AD21 - Selector - 2Pos - 1NO

  • $11.55

Harmony XB5, Selector switch, plastic black, Ø22, 2 positions, stay put, 1 NO

Out Of Stock

This product is out of stock, submit your email and we will update once it restock.

range of product Harmony XB5
product or component type Selector switch
device short name XB5
bezel material Dark grey plastic
head type Standard
mounting diameter 22 mm
sale per indivisible quantity 1
shape of signaling unit head Round
type of operator Stay put
operator profile Black standard handle
operator position information 2 positions 90°
contacts type and composition      1 NO
contact operation Slow-break
connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1
height 42 mm
width 30 mm
depth 70 mm
terminals description ISO n°1 (13-14)NO
product weight 0.043 kg
resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
contacts usage Standard contacts
positive opening Without
torque value 0.14 N.m NO changing electrical state
mechanical durability 1000000 cycles
tightening torque 0.8…1.2 N.m conforming to EN 60947-1
shape of screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
contacts material Silver alloy (Ag/Ni)
short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current      10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-1
[Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
electrical reliability Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4
device presentation Complete product