Industrial Automation
XB5AA31 -Push Button - Green - 1NO
-
$10.43
Harmony XB5, Push button, plastic, flush, green, Ø22, spring return, unmarked, 1 NO
Out Of Stock
This product is out of stock, submit your email and we will update once it restock.
range of product | Harmony XB5 |
---|---|
product or component type | Push-button |
device short name | XB5 |
bezel material | Plastic Dark grey plastic |
head type | Standard |
fixing collar material | Plastic |
mounting diameter | 22 mm |
sale per indivisible quantity | 1 |
shape of signaling unit head | Round |
type of operator | Spring return |
operator profile | Green flush, unmarked |
contacts type and composition | 1 NO |
contact operation | Slow-break |
connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1 |
height | 42 mm |
---|---|
width | 30 mm |
depth | 52 mm |
terminals description ISO n°1 | (13-14)NO |
product weight | 0.037 kg |
resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
contacts usage | Standard contacts |
positive opening | Without |
operating travel | 2.6 mm (NO changing electrical state) 4.3 mm (total travel) |
operating force | 3.8 N NO changing electrical state |
mechanical durability | 10000000 cycles |
tightening torque | 0.8…1.2 N.m conforming to EN 60947-1 |
shape of screw head | Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver |
contacts material | Silver alloy (Ag/Ni) |
short-circuit protection | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 |
[Ith] conventional free air thermal current | 10 A conforming to EN/IEC 60947-5-1 |
[Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-1 |
[Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
electrical durability | 1000000 cycles AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C |
electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 |
device presentation | Complete product |
customizable | No |
customizable | 1 |
GCR BRIDGE | XB5AACUST01 |
compatibility code | XB5 |