Power Distribution
METSEPM5331 - Power Meter - 2DI/2DO - 35 Alarms - MID
-
$916.40
PM5331 Meter, Modbus, up to 31st H, 256K 2DI/2DO, 35 alarms, MID
Out Of Stock
This product is out of stock, submit your email and we will update once it restock.
range | PowerLogic |
---|---|
product name | PowerLogic PM5000 |
device short name | PM5331 |
product or component type | Power meter |
power quality analysis | Up to the 31st harmonic |
---|---|
device application | Power monitoring Multi-tariff |
type of measurement | Current Voltage Frequency Power factor Energy Active and reactive power |
supply voltage | 100...415 V AC 45...65 Hz 125...250 V DC |
network frequency | 50 Hz 60 Hz |
[In] rated current | 1 A 5 A |
type of network | 1P + N 3P 3P + N |
maximum power consumption in VA | 10 VA at 415 V |
ride-through time | 80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical |
display type | Backlit LCD |
display resolution | 128 x 128 pixels |
sampling rate | 64 samples/cycle |
measurement current | 10…9000 mA |
analogue input type | Voltage (impedance 5 MOhm) Current (impedance 0.3 mOhm) |
measurement voltage | 35…690 V AC 45...65 Hz between phases 20…400 V AC 45...65 Hz between phase and neutral |
frequency measurement range | 45…65 Hz |
number of inputs | 2 digital |
measurement accuracy | Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.005 Current +/- 0.5 % Voltage +/- 0.5 % |
accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
number of outputs | 2 relay 2 digital |
information displayed | Tariff (4) |
communication port protocol | Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V JBUS |
communication port support | RS485 |
data recording | Alarm logs Min/max of instantaneous values Data logs Time stamping Maintenance logs Event logs |
memory capacity | 256 kB |
connections - terminals | Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 Relay output: screw terminal block4 Ethernet network: RJ45 connector |
mounting mode | Flush-mounted |
mounting support | Framework |
standards | EN 50470-3 IEC 62053-22 IEC 61557-12 UL 61010-1 IEC 62053-24 EN 50470-1 IEC 60529 |
product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 MID conforming to EN 50470-1 MID conforming to EN 50470-3 |
width | 96 mm |
depth | 72 mm |
height | 96 mm |
net weight | 430 g |