LV847283

Call Us +65 8693 8729
phone 0
phone 0
Product

Power Distribution

LV847283

  • $1,841.70

Micrologic 5.0 X control unit, for Masterpact MTZ, fixed, LSI protections

Out Of Stock

This product is out of stock, submit your email and we will update once it restock.

range Masterpact
device short name Micrologic 5.0 X
product or component type Control unit
device application Equipment protection, monitoring and control
circuit breaker application Distribution IEC standard
range compatibility Masterpact MTZ1 circuit breaker
Masterpact MTZ2 circuit breaker
Masterpact MTZ3 circuit breaker
Poles 3P
4P
Protected poles 3P 3d
4P 4d
4P 3d
4P 3d + N/2
4P 3d + OSN
[Ue] rated operational voltage      690 V AC, +/- 10 %
network type AC
network frequency 50/60 Hz
trip unit technology Electronic
trip unit protection functions LSI
protection type Overload protection (long time) conforming to ANSI 49
Instantaneous short-circuit protection conforming to ANSI 50
Short time short-circuit protection conforming to ANSI 51
trip unit rating 400 A
4000 A
1250 A
2500 A
800 A
6300 A
1600 A
2000 A
3200 A
630 A
1000 A
5000 A
mounting mode Fixed
[Ir] long time pick-up adjustment range 0.4...1 x In adjustable in step of 1 A
long time delay adjustment type Adjustable in step of 0.5 s
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
thermal memory Yes
[Isd] short-time pick-up adjustment range 1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or Masterpact MTZ mobile app
short-time delay adjustment type Adjustable
[tsd] short-time delay adjustment range 0.1…0.4 s I²t=on
0…0.4 s I²t=off
instantaneous pick-up adjustment type Ii Adjustable
[Ii] instantaneous pick-up adjustment range 2...15 x In adjustable in step of 0.5 x In with embedded HMI
2...15 x In adjustable in step of 0.1 x In with Ecoreach software or Masterpact MTZ mobile app
Ii enable on/off
[li mode] instantaneous delay adjustment range      0 ms in fast
20 ms in standard
zone selective interlocking ZSI With
network and machine diagnosis type System (HMI) health state overview: circuit breaker health state standard)
Contacts state: circuit breaker health state standard)
Micrologic service life: circuit breaker health state standard)
Tripping cause indication: circuit breaker tripping cause standard)
Identification card: diagnostic data standard)
Configured alarms synthesis: diagnostic data standard)
Monitored function: diagnostic data standard)
Operation: diagnostic data standard)
Micrologic test: test standard)
Protection test: test standard)
Selectivity test: test standard)
Trip context information: crisis management standard)
Operation: advanced diagnostic standard)
Breaker service life: circuit breaker health state standard)
type of measurement Power meter
energy management Measurement, active, reactive and apparent energy (standard)
Measurement, electrical network (standard)
Measurement, energy (standard)
metering type Current I1, I2, I3, In, Ig: maximum standard)
Average voltage Vavg standard)
Active power P, P1, P2, P3 standard)
Reactive power Q, Q1, Q2, Q3 standard)
Apparent power S, S1, S2, S3 standard)
Power factor standard)
Frequency standard)
Total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard)
Total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard)
Voltage V21, V32, V13, V1, V2, V3: instantaneous standard)
Voltage V21, V32, V13, V1, V2, V3: minimum standard)
Voltage V21, V32, V13, V1, V2, V3: maximum standard)
Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard)
Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard)
Demand current I1, I2, I3, In, Iavg standard)
Demand power P, Q, S standard)
measurement voltage 145.6…828 V AC 50/60 Hz per phase
frequency measurement range 45…250 Hz
measurement accuracy Power factor: +/- 1 %
Active energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh
Reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh
Apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh
Unbalance current: +/- 0.5 %
Frequency: +/- 0.005 Hz
Voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V
Voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V
Apparent power S, S1, S2, S3, Sdemand: +/- 1 %
Active power P, P1, P2, P3, Pdemand: +/- 1 %
Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
accuracy class Class 5: total current harmonic distortion THD (I)
Class 0.5: unbalance voltage
Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h)
Class 2: total voltage harmonic distortion THD (V)
display type LCD display - 128 x 96 pixels
communication port protocol Bluetooth 4.0 LE peer to peer 30 kbit/s
NFC peer to peer conforming to ISO 15963
USB peer to peer 115 kbauds
data recording Data logs
Time stamping
Alarm logs
Min/max of instantaneous values
Event logs
Maintenance logs