LTMEV40FM - Extension Module - 4 Inputs - 240VAC
-
$540.61
Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 100 to 240 VAC
Out Of Stock
This product is out of stock, submit your email and we will update once it restock.
range | TeSys |
---|---|
product name | TeSys T |
device short name | LTME |
product or component type | Extension module |
device application | Equipment monitoring and control |
range compatibility | TeSys T LTMR motor controller |
supply | Via the controller |
[Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
---|---|
[Uimp] rated impulse withstand voltage | 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 |
logic input number | 4 |
input current | 3.1 mA at 100 V 7.5 mA at 240 V |
current state 0 guaranteed | Logic input: 0...40 V and 2...15 mA for 25 ms |
current state 1 guaranteed | Logic input: 79...264 V and <= 15 mA for 25 ms |
maximum output switching frequency | 2 Hz |
maximum operating rate | 1800 cyc/h |
contacts type and composition | Without |
metering type | Imbalance voltage Active power P, P1, P2, P3 Calculated active and reactive energy (+/- W.h, +/- VAR.h) Voltage U21, U32, U13, V1, V2, V3 Reactive power Q, Q1, Q2, Q3 Frequency Power factor |
measurement accuracy | 1 % voltage (100...830 V) 3 % power factor 5 % active and reactive power |
overvoltage category | III |
connection pitch | 5.08 mm |
connections - terminals | Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end |
tightening torque | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm |
pollution degree | 3 |
electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 |
width | 45 mm |
height | 61 mm |
depth | 120.7 mm |
net weight | 0.21 kg |
compatibility code | LTME |