The Schneider Electric Acti9 Vigi iC60 is a modular earth‑leakage (residual current) add‑on block designed to be mounted directly with Acti9 iC60 miniature circuit breakers. When combined, the pair provides RCBO‑like protection(earth leakage + the MCB’s overload/short‑circuit protection) while keeping a modular layout.


What Vigi iC60 does

When connected to an iC60 MCB (N/H/L/Reflex variants), Vigi iC60 adds:

  • Earth‑leakage (residual current) protection for shock and fire risk
  • Voltage‑independent tripping
  • Isolation function (when combined with iC60)
  • ❌ No overload or short‑circuit protection by itself (this remains the iC60’s role)

Together, iC60 + Vigi iC60 = modular RCBO solution.


Key technical characteristics (typical)

Residual current protection

  • Sensitivities (IΔn): commonly 30 mA(personal protection) and 300 mA(fire protection)
  • Protection classes:
    • Type AC – sinusoidal AC leakage
    • Type A – AC + pulsating DC (recommended for modern loads)
    • Type A‑SI (Super‑Immunised) – higher immunity to nuisance tripping
  • Trip time: instantaneous (unless selective type is chosen)
  • Technology: voltage‑independent residual current detection

Electrical & mechanical

  • Poles: typically 2P(single‑phase) and 4P(three‑phase)
  • Rated current compatibility: up to 63 A(matched to the iC60)
  • Rated operational voltage: 230–240 V AC(up to 415 V AC depending on model)
  • Standards: IEC / EN 61009‑1
  • Mounting: clip‑on DIN rail, direct interface to iC60
  • IP rating: IP20 (IP40 in enclosure)

Diagnostics & safety (Acti9 features)

  • VisiTrip™: red mechanical indicator showing earth‑leakage trip
  • VisiSafe™: green window confirms full contact separation (safe maintenance)
  • Robust terminals and unified wiring design with iC60

How it’s used in a panel

Common arrangements:

  • Outgoing circuit protection where iC60 provides overcurrent/short‑circuit, Vigi iC60 adds earth‑leakage
  • Selective coordination(e.g., 300 mA upstream, 30 mA downstream)
  • Modular flexibility —add or change leakage sensitivity without replacing the MCB

Vigi iC60 vs iDPN Vigi (RCBO)

Feature Vigi iC60 + iC60 iDPN Vigi RCBO
Form Modular add‑on All‑in‑one
Breaking capacity Depends on iC60 (can be very high) Typically 6 kA
Flexibility High (change Vigi type/sensitivity) Fixed per device
Typical use Commercial/industrial, higher fault levels Residential/light commercial

Typical applications

  • Commercial and industrial distribution boards
  • Circuits near higher fault levels (use with iC60N/H)
  • Situations needing Type A‑SI immunity
  • Modular upgrades where RCCB functionality is required per circuit


Filters

Filters