Power Distribution
C10F34V100 - MCCB - NSX - Vigi - 100 A
-
$1,874.00
Circuit breaker ComPacT NSX100F, 36kA at 415VAC, MicroLogic 4.2 Vigi trip unit 100A, 3 poles 3d
Out Of Stock
This product is out of stock, submit your email and we will update once it restock.
range | ComPacT new generation |
---|---|
product name | ComPacT NSX new generation |
range of product | ComPacT NSX100...250 new generation |
device short name | NSX100F |
product or component type | Earth leakage circuit breaker |
device application | Distribution |
poles description | 3P |
protected poles description | 3t |
[In] rated current | 100 A at 40 °C |
[Ue] rated operational voltage | 440 V AC 50/60 Hz |
network type | AC |
network frequency | 50/60 Hz |
suitability for isolation | Yes conforming to EN/IEC 60947-2 |
utilisation category | Category A |
[Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Performance level | F 36 kA 415 V AC |
trip unit name | Micrologic 4.2 |
trip unit technology | Electronic |
trip unit protection functions | LSoIR |
control type | Toggle |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz |
---|---|
[Uimp] rated impulse withstand voltage | 8 kV |
[Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
mechanical durability | 50000 cycles |
electrical durability | 30000 cycles at 440 V In 50000 cycles at 440 V In/2 |
mounting support | Backplate |
upside connection | Front |
downside connection | Front |
connection pitch | 35 mm |
protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection R : for earth-leakage protection |
trip unit rating | 100 A at 40 °C |
Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
[Ir] long-time protection pick-up adjustment range | 40...100 A |
Long-time protection delay adjustment type tr | Fixed |
[tr] long-time protection delay adjustment range | 11 s at 7.2 x Ir 16 s at 6 x Ir 400 s at 1.5 x Ir |
thermal memory | 20 minutes before and after tripping |
Short-time protection pick-up adjustment type Isd | Adjustable |
[Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
Short-time protection delay adjustment type tsd | Fixed |
[tsd] Short-time protection delay adjustment range | 0.02 s |
Instantaneous protection pick-up adjustment type Ii | Fixed |
[Ii] instantaneous protection pick-up adjustment range | 1500 A |
earth-leakage protection | Integrated |
earth-leakage protection class | Class A |
Earth-leakage protection sensitivity adjustment type IΔn | Adjustable |
[IΔn] earth-leakage protection sensitivity adjustment range | 30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A |
Earth-leakage protection specific mode | OFF using the IΔn rotary switch |
Earth-leakage protection time delay adjustment type Δt | Adjustable |
[Δt] Earth-leakage protection time delay adjustment range | 0 ms 60 ms 150 ms 500 ms 1 s |
Number of slots for electrical auxiliaries | 5 slot(s) |
local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
Width (W) | 105 mm |
Height (H) | 161 mm |
Depth (D) | 86 mm |
net weight | 2.05 kg |