Power Distribution
56272 - Earth Leakage Relay - 130VAC
-
$226.10
residual current protection relay, VigiPacT RH99P, 30 mA to 30 A, 110/130 VAC 50/60 Hz, front panel mounting
Out Of Stock
This product is out of stock, submit your email and we will update once it restock.
range | VigiPacT |
---|---|
device short name | RH99P |
product or component type | Residual current protection relay |
relay application | Protection relay |
mounting support | Front panel |
earth-leakage protection class | Type A |
type of setting | Selector |
residual earth-leakage sensitity adjustment type | Adjustable 9 settings |
Earth-leakage sensitivity | 0.03…30 A |
Earth-leakage time delay | Instantaneous for 0.03 A Adjustable 9 settings 0…4.5 s for 0.03…30 A |
Current sensors compatibility | TOA earth leakage current sensor A earth leakage current sensor L earth leakage current sensor |
[Ithe] conventional enclosed thermal current | 8 A |
minimum load | 10 mA at 12 V |
[Us] rated supply voltage | 110...130 V AC 50/60 Hz 55...110 % |
power consumption in VA | 4 VA |
Monitored distribution system | 1000 V - AC at 50/60 Hz (maximum) 1000 V - AC at 400 Hz (maximum) |
earthing system | TN-S IT TT |
[Uimp] rated impulse withstand voltage | 8 kV |
reset | Manual reset |
test function | Remote test Local |
---|---|
monitoring | Electronics (continuous) Power supply (continuous) Relay/sensor link (continuous) |
type of measurement | Earth fault current internal measurement, range: 80...100 % |
tamperproof of settings | Protected by sealable cover |
connections - terminals | Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12 Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 Fault: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Fault: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12 Fault: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Relay test and fault reset: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12 Relay test and fault reset: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 Sensor: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Sensor: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12 Sensor: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 Voltage presence: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24...AWG 12 Voltage presence: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24...AWG 12 Voltage presence: terminal block cable(s) 0.25…2.5 mm² flexible AWG 24...AWG 12 |
wire stripping length | Auxiliary power supply: 7 mm Fault: 7 mm Relay test and fault reset: 7 mm Sensor: 7 mm Voltage presence: 7 mm |
tightening torque | Auxiliary power supply: 0.6 N.m Fault: 0.6 N.m Relay test and fault reset: 0.6 N.m Sensor: 0.6 N.m Voltage presence: 0.6 N.m |
width | 72 mm |
height | 72 mm |
depth | 78 mm |
cut-out dimensions | 68 x 68 mm |
net weight | 0.3 kg |
IP degree of protection | IP40 on front face: conforming to EN/IEC 60529 IP30 on side parts: conforming to EN/IEC 60529 IP20 on connection terminals: conforming to EN/IEC 60529 |
IK degree of protection | IK07 conforming to EN 50102 |
mechanical robustness | Fire resistance conforming to IEC 60695-2-1 IK protection 2 joules: IK07 conforming to EN 50102 Vibrations 13.2...100 Hz: 0.7 g Vibrations 2...13.2 Hz: +/- 1 mm |