Schneider Electric | 33466 | Moulded Case Circuit Breaker

Call Us +65 8693 8729
phone 0
phone 0
Product

Power Distribution

33466 - MCCB - 800A - 3P

  • $2,307.55

circuit breaker ComPact NS800N, 50 kA at 415 VAC, Micrologic 2.0 trip unit, 800 A, fixed, 3 poles 3d

Out Of Stock

This product is out of stock, submit your email and we will update once it restock.

rangeComPact
product nameComPact NS
range of productComPact NS630b...1600
device short nameCompact NS800N
product or component typeCircuit breaker
device applicationDistribution
Number of poles3P
protected poles description3d
(In) rated current up to 65 °C800 A at 50 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
network typeAC
network frequency50/60 Hz
suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory B
[Icu] rated ultimate short-circuit breaking capacity     30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
trip unit nameMicrologic 2.0
trip unit technologyElectronic
trip unit protection functionsLI
control typeRotary handle
Toggle
Circuit breaker mounting modeFixed
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current19.2 kA 1 s conforming to IEC 60947-2
mechanical durability10000 cycles
electrical durability2000 cycles at 690 V In
4000 cycles at 690 V In/2
5000 cycles at 440 V In
6000 cycles at 440 V In/2
power losses15 W
mounting supportBackplate
upside connectionFront
downside connectionFront
connection pitch70 mm
protection typeL : for overload protection (long time)
I : for instantaneous short-circuit protection
trip unit rating800 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection)     Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Long-time protection delay adjustment type trAdjustable 9 settings
[tr] long-time protection delay adjustment range12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.7…16.6 s at 7.2 x Ir
thermal memory20 mn
Instantaneous protection pick-up adjustment type IiAdjustable
[Ii] instantaneous protection pick-up adjustment range1.5...10 x Ir
earth-leakage protectionWithout
auxiliary contact composition1 NO/NC
local signalling4 LEDs (red) for fault indication
1 LED (yellow) for overload
Width (W)210 mm
Height (H)327 mm
Depth (D)147 mm
net weight14 kg